X127 Lan (Ethernet) - Siemens SINAMICS S120 Equipment Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Note
The two "+" and/or "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
The current consumption increases by the value for the DRIVE-CLiQ participant and digital
outputs.
8.3.2.8

X127 LAN (Ethernet)

Table 8- 10
X127 LAN (Ethernet)
Pin
1
2
3
4
5
6
7
8
Connector type
RJ45 socket
Note
The Ethernet interface supports Auto MDI(X). It is therefore possible to use both crossed and
uncrossed cables to connect the devices.
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
Control Units, Control Unit Adapters and operating components
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
8.3 Control Unit CU310-2 PN (PROFINET)
Technical data
Ethernet transmit data +
Ethernet transmit data -
Ethernet receive data +
-
-
Ethernet receive data -
-
-