Code
E36
VALVE
INTERFACE
FILTRATION AND TOP OFF DISABLED - CALL
SERVICE
E37
AUTOMATIC
PROBE FAILURE - FILTRATION DISABLED - CALL
SERVICE
E39
CHANGE FILTER PAD
E41
OIL IN PAN ERROR
E42
CLOGGED DRAIN (Gas)
E43
OIL SENSOR FAILURE - CALL SERVICE
E44
RECOVERY FAULT
E45
RECOVERY FAULT – CALL SERVICE
E46
SYSTEM INTERFACE BOARD 1 MISSING - CALL
SERVICE
E51
DUPLICATE BOARD ID - CALL SERVICE
E52
USER INTERFACE CONTROLLER ERROR - CALL
SERVICE
E53
CAN BUS ERROR - CALL SERVICE
E54
USB ERROR
E55
SYSTEM INTERFACE BOARD 2 MISSING - CALL
SERVICE
E61
MISCONFIGURED ENERGY TYPE
E62
VAT NOT HEATING – CHECK ENERGY SOURCE –
XXXF OR XXXC
E63
RATE OF RISE
E64
FILTRATION INTERFACE BOARD FAILURE -
FILTRATION AND TOP OFF DISABLED - CALL
SERVICE
E65
CLEAN OIB SENSOR – XXX F OR XXX C - CALL
SERVICE
E66
DRAIN VALVE OPEN – XXXF OR XXXC
E67
SYSTEM INTERFACE BOARD NOT CONFIGURED
- CALL SERVICE
E68
OIB FUSE TRIPPED – CALL SERVICE
E69
RECIPES NOT AVAILABLE – CALL SERVICE
ERROR MESSAGE
BOARD
FAILURE
INTERMITTENT
FILTRATION
-
Valve Interface Board connections lost or
board failure.
AIF RTD reading out of range.
25-hour timer has expired or dirty filter
logic has activated.
The system detects that oil may be present
in the filter pan.
Vat did not empty during filtration
Oil level sensor may have failed.
Recovery time exceeded maximum time
limit.
Recovery time exceeded maximum time
limit for two or more cycles.
SIB board 1 connection lost or board
failure.
Two or more controllers have the same
location ID.
The controller has an unknown error.
Communications are lost between boards.
USB connection lost during an update.
SIB board 2 connection lost or board
failure.
The fryer is configured for the incorrect
energy type.
The vat is not heating properly.
Rate of rise error occurred during a
recovery test.
Filtration Interface Board connections lost
or board failure.
Gas -The oil is back sensor does not detect
oil. Clean oil sensor.
Drain valve is opened during cooking.
Controller is turned on when the SIB board
is not configured.
The VIB board OIB fuse has tripped and
didn't reset.
The controller has not been programmed
with product recipes.
5-9
EXPLANATION
Replace controller

Advertisement