Download Print this page

Frymaster FilterQuick easyTouch FQE30U Installation, Operation And Maintenance Manual page 21

Advertisement

WARNING
Do not add HOT or USED
oil to a JIB.
3.3.3 Bulk Oil Systems
Instructions for installing and using bulk oil systems are found in Appendix A located at the
rear of this manual.
3.4 Filtration
3.4.1 Introduction
The FilterQuick
with fingertip filtration system allows the oil in one frypot to be safely and
efficiently filtered while the other frypots in a battery remain in operation.
Section 3.4.2 covers preparation of the filter system for use. Operation of the system is covered in
the FilterQuick Touch Controller Manual.
The on-site supervisor is responsible for ensuring that operators are made aware of the
inherent hazards of operating a hot oil filtering system, particularly the aspects of oil
filtration, draining and cleaning procedures.
The filter pad or paper MUST be replaced daily or when the sediment level exceeds the
height of the hold down ring.
5. Slide the JIB onto the shelf inside the fryer cabinet (as
seen in Figure 3).
6. Press the JIB reset switch to clear the Top Off Empty
display on the FQ4000 controller off (see Figure 7).
WARNING
WARNING
3–5
Figure 7

Advertisement

loading