FortiGate-7040E chassis
To connect the FortiGate-7040E chassis to ground
Chassis
Ground
Connector
Data Center
1. Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal surface on the chassis or frame.
2. Make sure that the chassis and ground wire are not energized.
3. Connect the green ground wire from the local ground to the ground connector on the FortiGate-7040E chassis.
4. Secure the ground wire to the chassis.
5. Optionally label the wire GND.

Turning on FortiGate-7040E chassis power

Connect AC or DC power to PWR1, PWR2 and PWR4. Once the FortiGate-7040E chassis is connected to power the
chassis powers up. If the chassis is operating correctly, the LEDs on the PSUs and fans should be lit. As well, the LEDs
on the FortiGate-7040E management module should be lit.
When the chassis first starts up you should also hear the cooling fans operating.
In addition, if any modules have been installed in the chassis they should power on and their front panel LEDs should
indicate that they are starting up and operating normally.