Fan Tray Failure; Configuration Terminal Issues; No Display; Garbled Display - H3C S6520X-SI Series Installation Manual

Hide thumbs Also See for S6520X-SI Series:
Table of Contents

Advertisement

If the issue persists, contact H3C Support.
4.
To replace a power module, see

Fan tray failure

The S6520X-SI switches (except the S6520X-26XC-UPWR-SI and S6520X-54XC-UPWR-SI) use
built-in fan trays. If a fan tray fails, contact H3C Support.
The S6520X-26XC-UPWR-SI and S6520X-54XC-UPWR-SI switches use removable fan trays. If an
LSPM1FANSB fan tray fails, the fan tray Alarm LED turns on and the switch sends alarm messages.
You can see

Configuration terminal issues

If the configuration environment setup is correct, the configuration terminal displays booting
information when the switch is powered on. If the setup is incorrect, the configuration terminal
displays nothing or garbled text.

No display

Symptom
The configuration terminal does not have display when the switch is powered on.
Solution
To resolve the issue:
Verify that the power module is supplying power to the switch correctly.
1.
Verify that the console cable is correctly connected.
2.
Verify that the console cable does not have any issues and the terminal settings are correct.
3.
If the issue persists, contact H3C Support.
4.

Garbled display

Symptom
The display on the configuration terminal is garbled.
Solution
To resolve the issue:
Verify that the following settings are configured for the terminal:
1.
Baud rate—9600.
Data bits—8.
Stop bits—1.
Parity—None.
Flow control—None.
If the issue persists, contact H3C Support.
2.
"Installing and removing a power
"Installing and removing a fan
tray" to replace the fan tray.
45
module."

Hide quick links:

Advertisement

Table of Contents
loading