Viessmann Vitocal 300-G Series Installation And Service Instructions Manual page 107

Heat pump with electric drive
Table of Contents

Advertisement

Control parameter report
Photovoltaics
Parameter
"Enable own energy consumption PV"
"Prop. of external current"
"Threshold for electrical power"
"Enable own energy consumptn for set
DHW temperature 2"
"Enable own energy consumption for
DHW heating"
"Enable own energy consumptn for heat-
ing water buffer cyl."
"Enable own energy consumption for
heating"
"Enable own energy consumption for
cooling"
"Raise set DHW cylinder temperature
PV"
"Raise set heating water buffer cylinder
temp PV"
"Raise set room temperature PV"
"Reduce set room temperature PV"
Smart Grid
Parameter
"Enable Smart Grid"
"Smart Grid Enable elec heat"
"Smart Grid set value increase for DHW
heating"
"Smart Grid set value increase for htg
wtr buff"
"Smart Grid set value increase for centr
htg"
"Smart Grid set value decrease for room
t cool"
Time
Parameter
"Automatic changeover summertime -
wintertime"
"Start summertime - month"
"Start summertime - week"
"Start summertime - day"
"Start wintertime - month"
"Start wintertime - week"
"Start wintertime - day"
(cont.)
Code
Factory setting
7E00
0
7E02
10 (
7E04
0 (
7E10
0
7E11
0
7E12
0
7E13
0
7E15
0
7E21
0 (
7E22
0 (
7E23
0 (
7E25
0 (
Code
Delivered condition Commission-
7E80
0
7E82
0
7E91
0 (
7E92
0 (
7E93
0 (
7E95
0 (
Code
Delivered condition Commission-
7C00
1
7C01
3
7C02
5
7C03
7
7C04
10
7C05
5
7C06
7
Commissioning/service reports
Commission-
ing
10 %)
0 W)
0 K)
0 K)
0 K)
0 K)
ing
0 K)
0 K)
0 K)
0 K)
ing
Maintenance/
service
Maintenance/
Service
Maintenance/
Service