Installation Of Transducers - Furuno TZT12F Installation Manual

Multi-function display
Hide thumbs Also See for TZT12F:
Table of Contents

Advertisement

1. MOUNTING
3. Set the TZT12F unit to the hanger and tighten the knob bolts.
Knob bolt
1.2

Installation of Transducers

Note: For instructions regarding installation of network fish finder transducers, see the
respective manual.
There are three methods for installing the
transducer on the ship (thru-hull mount, in-
side the hull and transom mount) and one of
those methods is to be selected according to
the structure of the ship. The procedure
which follows below shows how to install a
small transducer (520-5PSD/5MSD) as the
representative example of installation.
1-6
CAUTION
Do not cover the transducer with FRP resin.
The heat generated when the resin hardens
may damage the transducer. CHIRP transduc-
ers are especially vulnerable to heat.
Hanger
ø22
120
30
68
520-5PSD
Knob bolt
ø24
120
28
Unit: mm
68
BOW
87
520-5MSD