Water Pressure Gauge; Canbus Connections - BRP Evinrude E-Tec Series Service Manual

115,150,175,200 hp, 60 v models
Hide thumbs Also See for Evinrude E-Tec Series:
Table of Contents

Advertisement

Water Pressure Gauge

If a mechanical water pressure gauge is used,
install the water pressure hose fitting in the cylin-
der block. Use Pipe Sealant with Teflon,
P/N 910048, on the threads of the hose fitting.
Refer to installation instructions supplied with
gauge.
Route the water pressure hose around the star-
board side of the powerhead along the same path
as the battery cables.
1. Water pressure hose fitting
After installation, make sure there
IMPORTANT:
is enough clearance for all cables to avoid binding
or chafing through all engine steering and tilting
angles.

CANbus Connections

If the outboard will be used with an I-Command
system, or other NMEA 2000
instruments, the following connections will supply
information to the network:
Use a CANbus Ignition Harness, in place of the
standard MWS harness, to connect the outboard
to the key switch and trim/tilt control. Seal unused
1
004959
compliant CANbus
INSTALLATION AND PREDELIVERY
SystemCheck connector with 6-Pin Connector
Seal, P/N 586076.
1
1. CANbus Ignition connector
2. Trim/Tilt connector
3. SystemCheck connector (with seal)
Connect the EMM CANbus connector to the CAN-
bus Network Harness.
1. EMM CANbus connector
Route the harness under the front of the EMM and
around the port side of the powerhead. Secure
with tie straps.
1
1. Harness routing
2. Tie straps