Installing Cards In The Wall-Mounted Cabinet - Nortel 1000 Manual

Fiber remote ipe fundamentals
Table of Contents

Advertisement

16
Connect the NT1P70 main cabinet to the NTAK12 expansion
cabinet by installing the cable between connector P1 of the main
cabinet and P1 of the expansion cabinet.
This completes the cabinet installation and system ground test. Now install
the plug-in cards.

Installing cards in the wall-mounted cabinet

This section describes how and where to install the cards in the Fiber
Remote IPE cabinet. Even though the cards are shipped in the cabinet
from the factory, for safety and ease of installation, these cards were
removed from the cabinet before installing it onto the wall.
NT1P63 Electro-optical packlets, which are installed on the NT1P62 Fiber
Peripheral Controller card, are normally installed in the factory; however, it
may be necessary to install an additional NT1P63 Electro-optical packlet
on the NT1P62 Fiber Peripheral Controller card to make a single fiber-optic
link into a redundant link.
Follow the steps in
cabinet" (page 71)
Procedure 11
Installing cards in the wall-mounted cabinet
Step
Action
1
Pull the NT1P62 Fiber Peripheral Controller card's locking
devices away from the faceplate.
While holding the card by these devices, insert the card into the
card guides in slot 0.
Refer to
75)
2
Slide the card into the cabinet until it engages the backplane
connector, and then push the locking device levers towards
the faceplate to insert the card connector into the backplane
connector and lock the card in place.
3
If not already installed, install the NT1P63 Electro-optical packlet
on the NT1P62 Fiber Peripheral Controller card.
Insert the NT1P63 Electro-optical packlet, connector first,
through the NT1P62 Fiber Peripheral Controller card faceplate
opening and plug it into the connector on the NT1P62 Fiber
Peripheral Controller card.
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Wall-mounted Fiber Remote IPE installation 71
Procedure 11 "Installing cards in the wall-mounted
to install the cards in the wall-mounted cabinet.
Figure 16 "Link connections on the IPE cabinet" (page
for card positions in the shelf.
Nortel Communication Server 1000
Fiber Remote IPE Fundamentals
NN43021-554 04.01 4 June 2010