Unlatch the card's locking devices by squeezing the tabs and
pulling the upper locking device away from the card and the
lower locking device downwards.
6
Pull the card out of the IPE module or cabinet and place it in an
antistatic bag away from the work area.
7
Check the replacement card and make sure that the
Electro-optical packlets are already installed.
If not installed, install the new packlets or remove the packlets
from the faulty Fiber Peripheral Controller card and install them
on the replacement card if sure the packlets are not faulty.
8
Hold the replacement card by the card locking devices and insert
it partially into the card guides in the module.
9
Pull the upper locking device away from the faceplate on the
card and the lower locking device downwards and insert the card
firmly into the backplane connector.
Press the upper locking device firmly against the faceplate and
the lower locking device upwards to latch the card inside the
module.
The Fiber Peripheral Controller card automatically starts the
self-test.
10
Observe the red LED on the front panel during self-test.
If the red LED flashes three times and stays lit, it has passed the
test. Go to step 11.
If the red LED does not flash three times and stay lit, it has failed
the test. Pull the card partially out of the module and reinsert it
firmly into the module. If the problem persists, troubleshoot or
replace the Fiber Peripheral Controller card.
11
Connect the fiber-optic patchcords to the optical connectors of
the Fiber Peripheral Controller card faceplate.
For a wall-mounted Fiber Remote IPE, plug the fiber-optic link
FC/PC optical connectors into the FC/PC optical connectors on
the Fiber Peripheral Controller card faceplate.
12
At the: prompt in the LD 32 program, type ENXP x, where x is
the Fiber Peripheral Controller card, and press the Enter key to
enable the card.
If the uppermost red LED on the Fiber Peripheral Controller
card faceplate turns off, the card is functioning correctly and is
enabled.
The outcome of self-test is also indicated by LD 32 on the MMI
terminal connected to the Fiber Peripheral Controller card. If the
LED stays lit, go to
replace the card.
Nortel Communication Server 1000
Fiber Remote IPE Fundamentals
NN43021-554 04.01 4 June 2010