6.1
Both Sides Adjustment
16
Select whether to continue the scan measure-
ment or to finish the scan measurement and
calculate the adjustment value.
% To continue the scan measurement, press
[No]. To finish the scan measurement and
calculate the adjustment value, press [Yes].
% Pressing [No] returns to the [Scan Adjust-
ment Chart] screen on which the counter of
[Chart Sheets] is added by one. Repeat
steps 12 to 15 for the number of adjustment
charts. The measurement results will be
added up. This operation can be repeated
up to 20 times.
% Pressing [Yes] automatically calculates the
adjustment value from the added measure-
ment results and reflects it on Zoom and Image Shift in [Back], and the setting in [Rotate/Skew]. Af-
ter pressing [Yes], output a sheet of the adjustment chart to confirm the result. If readjustment is
needed, repeat steps 8 to 16.
% If the adjustment value obtained by pressing [Yes] exceeds the available adjustment range, a mes-
sage is displayed indicating that the available adjustment range has been exceeded. Press [Close]
to discard the adjustment value, then retry scan measurement from the beginning.
% Possible causes to exceed the adjustment range may include that the chart used in the scan meas-
urement is incorrect (a different chart has been used), the printing position of the front side has been
poorly adjusted, or the adjustments of the reference positions are not completed. Confirm these
points before restarting the scan measurement.
% If [Back Side Magnification Adjustment] is set to [OFF], the zoom ratio in the paper feed direction
will not be adjusted.
17
After the adjustment is completed, press [OK].
To finely adjust the adjustment value, continu-
ously proceed to step 4 in "Zoom and Image
Shift Adjustment" (page 6-22).
% To register adjustment values in a paper
profile, press [Register & OK].
% For details about how to register a paper
profile, refer to the [HTML User's Guide].
18
Press [Close] to exit the adjustment.