Toner Supply Motor On Time Determinations - Ricoh Russian-C2a Service Manual

Table of Contents

Advertisement

DEVELOPMENT

Toner Supply Motor On Time Determinations

For fixed control mode, the toner supply motor on time is specified by the setting of
SP2-925, and does not vary. The default setting is 200 ms for each copy. The
toner supply motor on time for each value of SP2-925 is as follows.
Value of SP2-925
0
1
2
3
4
5
6
7
For sensor control modes 1 and 2, the toner supply motor on time is decided by the
following factors.
• ∆Vt (= Vt – (Vref or Vts))
• TD sensor sensitivity (coefficient: S,
There are seven levels for toner supply motor on time as shown below.
Level
0 < ∆Vt ≤ S/16
1
S/16 < ∆Vt ≤ S/8
2
S/8 < ∆Vt ≤ S/4
3
S/4 < ∆Vt ≤ S/2
4
S/2 < ∆Vt ≤ 4S/5
5
4S/5 < ∆Vt ≤ S (near-end)
6
S < ∆Vt (toner end)
7
NOTE: 1) The value of "t" can be changed using SP2-922 (default: 0.6 second)
2) The value of "T" can be changed using SP2-923 (default: 30 seconds)
3) T (30) means that toner is supplied intermittently in
(1.5 s on, 1.5 s off)
Motor On Time (t = 200 ms)
t
2t
4t
8t
12t
16t
Continuously
Not supplied
Decision
for 30 seconds
2-40
value is
0.3)
Motor On Time (seconds)
t (0.6)
t x 2 (1.2)
t x 4 (2.4)
t x 8 (4.8)
t x 16 (9.6)
T (30); see note 3
T (30); see note 3
10 August, 2001
a half duty cycle