Connector to the Motherboard (X44)
Pin No. Designation
1
RUN_G
2
RUN_R
3
TEMP_ERR
4
Ethernet_LED
5
DP_LED
6
HD_LED
7
SPEAKER
8
RESET_N
9
NC
10
NC
11
NC
12
NC
13
GND
14
USB_D1P
15
USB_D1M
16
P5V_fused
17
M_DATA
18
M_CLK
19
K_DATA
20
K_CLK
21
PWR button
22
GND
23
P5V_fused
24
Soft Off
25
P12V
26
GND
External Reset (X30) Type: JST B2B-PH-SM3-TB
Pin No.
1
2
The device is reset when pins 1 and 2 (for example, via button) are short circuited.
It remains in this state until the short circuit has been remedied.
SIMATIC Rack PC 840 Manual
A5E00104826-03
Description
LED watchdog o.k., anode with 330Ω
in series on motherboard
LED watchDog error, anode with
330Ω in series on motherboard
LED temperature error, anode with
330Ω in series on motherboard
Ethernet LED, anode above 330Ω in
series on motherboard
PROFIBUS/MPI LED, anode above
150Ω in series on motherboard
HD LED, anode with 150Ω in series
on motherboard
Connection for system speaker
Reset signal (low active)
Ground
USB data
USB data
+5V (fused)
Mouse DATA
Mouse clock
Keyboard data
Keyboard clock
Connection pin for On/Off button at
the front
Ground
+5V (fused)
Power LED (yellow), anode above
150Ω in series on motherboard
Ground
Designation
Description
PWRGood
External reset, (IO low max.
30 mA)
GND
Ground
Hardware Information
Input / Output
Output
Output
Output
Output
Output
Output
Output
Input
-
-
-
-
-
Input / Output
Input / Output
Output
Input / Output
Output
Input / Output
Output
Input
-
Output
Output
Output
-
Input / Output
7-33