The CRS-180 switch module's small size and weight allow it to be freestanding. You may choose
to let the module hang freely, supported only by the interfacing cables.
CEFD P/N
FP/PN11575-1
HW/6-32X3/8FLT

Figure 2-1. Optional Switch Mounting Kit (CEFD P/N KT/11708)

You may also mount the module in a 1RU space at the front or rear of the rack enclosure that
houses the modems. The optional Comtech EF Data KT/11708 Mounting Panel Kit is available for
this purpose. As shown in Figure 2-1, the module can be vertically or horizontally oriented to the
kit's slotted mounting panel. User-supplied screws are then required to secure the panel to the
rack enclosure threaded mounting rails.
CAUTION – PROPER GROUNDING PROTECTION IS REQUIRED. The equipment must be
connected to the protective earth connection at all times. It is therefore imperative
that the Switch and its paired modems are properly grounded – using the ground stud
provided on the Switch antenna side panel and the ground studs located on the
modem rear panels – during installation, configuration, and operation.
Comtech EF Data KT/11708 Switch Mounting Kit
Qty
Description
1
Switch Mounting Panel
4
#6-32 x 3/8" LG SS Flat Head Machine Screw
2–2
MN/CRS180.IOM
Revision 11