Disconnect power BEFORE making electrical connections. Below is an example of a wiring setup for door access. Door access can be
wired to Door 1, 2, 3, or 4 on the Door Boards.
RFID ANTENNA
with Wiegand output
Power for RFID ANTENNA
(Not Provided)
DO NOT use the power
supply for the controller
SUPERVISED (DOOR STATUS)
DOOR SENSOR
OR
(SUPERVISED)
EOL (End of Line) Resistor
(1k ohm)
*PRIMARY RELAY
DOOR STRIKE
Power for Door Strike
(Not Provided)
Use 18-22 AWG
For DC Power:
Install a 1N4005
diode or equivalent
MAGLOCK
Use 18-22 AWG
For DC Power:
Install a 1N4005
diode or equivalent
PRE-INSTALL
WIEGAND
KEYPAD
OR
DOOR SENSOR
(NON-SUPERVISED)
For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor)
(provided) or equivalent
COMMON
+
NORMALLY OPEN
OR
For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor) (provided)
or equivalent
NORMALLY CLOSED
COMMON
+
Power for Maglock
(Not Provided)
DO NOT use the power
supply for the controller
INSTALL
READER
OR
NOTE: For KPR2000
keypad, wire the pink and
black (ground) wires together.
REQUEST TO EXIT
PROXIMITY
PUSH
SENSOR
BUTTON
OR
REQUEST TO EXIT
NORMALLY OPEN
NORMALLY CLOSED
NORMALLY OPEN
AUXILIARY RELAY
Low
Voltage
Power
Supply
Isolation
Relay
NOTE: DO NOT
run high voltage
power within
the CAPXL
enclosure.
COMMON
NORMALLY OPEN
19
NETWORK
ACCESS CONTROL
NOTE: The length of the unshielded
wires should be kept to a minimum to
avoid electrical noise.
GROUND
SUPERVISED
COMMON
COMMON
DOOR 1, 2, 3, or 4
LIGHT
LOAD
LINE
OR
ALARM BYPASS
* NOTE: MAGLOCK, door strike
and ALARM BYPASS not
evaluated by UL.