System Messages
Number
70011
The system time could not be modified. This
may be due to the following:
an impermissible time was transferred in
the PLC job,
the Windows NT user has no user rights
to modify the system time.
70012
An error occurred when executing the
function "Exit Runtime" with the option "Exit
also Windows".
Windows and ProTool/Pro RT are not
terminated.
A possible cause is that other applications
cannot be terminated.
70013
The system time could not be modified
because an invalid value was entered.
Incorrect separators may have been used.
70014
The system time could not be modified. This
may be due to the following:
an impermissible time was transferred,
the Windows NT user has no user rights
to modify the system time,
Windows rejects the setting request.
70015
The system time could not be read because
Windows rejects the reading function.
70016
An attempt was made to select a screen by
means of a function or job. This is not
possible because the screen number
specified does not exist.
Or: a screen could not be generated due to
insufficient system memory.
80001
80002
A line is missing in the specified archive.
80003
The copying process for archiving was not
successful.
In this case, it is advisable to check any
subsequent system messages, too.
80006
Since archiving is not possible, this causes a
permanent loss of the functionality.
80009
A copying action has been completed
successfully.
80010
Since the path was incorrectly entered in
ProTool, this causes a permanent loss of the
functionality.
C-4
CuuDuongThanCong.com
Effect/Cause
Remedy
Check the time which is to be set.
Under Windows NT: The user executing
ProTool/Pro RT must be assigned the rights
to modify the system time from Windows NT
(administration/user manager, guidelines).
Terminate all applications currently running.
Then terminate Windows.
Check the time which is to be set.
Check the time which is to be set.
Under Windows NT: The user executing
ProTool/Pro RT must be assigned the rights
to modify the system time from Windows NT
(administration/user manager, guidelines).
Check the screen number in the function or
job with the screen numbers configured.
Refer the number to a screen, if necessary.
Store the file or table by executing a 'move'
or 'copy' function.
In the case of databases, check whether the
corresponding data source exists and start
up the system again.
Configure the path for the respective archive
again and restart the system when the full
functionality is required.
TP 170A Equipment Manual
https://fb.com/tailieudientucntt
Release 12/99