Check pilot fl ame pattern and burner fl ame pat-
terns often.
PILOT FLAME PATTERN
Figure 46 shows a correct pilot fl ame pattern.
Figure 47 shows an incorrect pilot fl ame pattern.
The incorrect pilot fl ame is not properly heating the
thermocouple. When the thermocouple cools, the
heater will shut down.
If pilot fl ame pattern is incorrect, as shown in
Figure 47.
• turn heater off (see To Turn Off Gas to Appliance,
Page 23)
• see Troubleshooting, Page 34
NOTE: The pilot fl ame on natural gas units will have
a slight curve, but fl ame should be blue and have
no yellow or orange color.
Thermocouple
Figure 46 - Correct Pilot Flame Pattern
Thermocouple
Figure 47 - Incorrect Pilot Flame Pattern
MAIN BURNER
Periodically inspect all burner fl ame holes with
the heater running. All slotted burner fl ame holes
should be open with yellow flame present. All
round burner fl ame holes should be open with
a small blue fl ame present. Some burner fl ame
holes may become blocked by debris or rust, with
no fl ame present. If so, turn off heater and let cool.
Remove blockage. Blocked burner fl ame holes may
create soot.
BURNER FLAME PATTERN
WARNING: If incorrect burner fl ame
pattern occurs your fi replace could
produce increased levels of carbon
monoxide.
NOTICE: Do not mistake orange fl ames
with yellow tipping. Dirt or other fi ne
particles are burned by fireplace,
causing brief patches of orange fl ame.
30

INSPECTING BURNERS

Figure 48 shows the correct burner fl ame.
The front ember burner should have a small blue
fl ame. When the ember material is applied, the
embers will glow red and the fl ame may have a few
small bright yellow tips less than 1/2 inch in height.
The middle burner produces a blue fl ame that im-
pinges upon the ceramic ramp causing the ramp to
glow red with an occasional yellow streak.
The rear burner produces a bright yellow fl ame with
the base of the fl ame being blue.
Figure 49 shows the incorrect burner fl ame.
The front ember burner should not produce yellow
fl ames greater than 1/2" in height or any dark yellow
or orange fl ames.
The middle burner should not produce fl ame that
remains yellow or yellow fl ame that extends above
Pilot Burner
the ceramic ramp.
The rear burner should not produce a dark yellow /
orange fl ame nor should it be absent of blue color
near the base of the fl ame next to the shiny stain-
less steel burner..
If burner fl ame pattern is incorrect, as shown in
Figure 49.
• turn fi replace off (see To Turn Off Gas to Appli-
Pilot Burner
• see Troubleshooting, Page 34
Middle burner
fl ame should
be blue with
the ramp/log
glowing orange/
red
Yellow tipping on
ember burner
SuperiorFireplaces.us.com
ance, Page 23)
Bright yellow rear
burner fl ame; fl ame
will be blue next to
burner
Figure 48 - Correct Burner Flame Pattern
Dark orange rear
burner fl ame
Figure 49 - Incorrect Burner Flame Pattern
Small blue
fl ame on
ember burner
with no yellow
tipping
Yellow or dark
orange middle
burner fl ame