INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper flame height.
Alterations may have occurred during shipping and handling. The
pilot is located on the back right hand side of the burner.
The height of the thermopile must be 3/8" to 1/2" above the pilot flame.
The flame from the pilot burner must extend beyond the thermopile.
If your pilot assembly does not meet these requirements:
• Turn adjustment screw marked pilot clockwise to decrease or
counterclockwise to increase the flame to proper size (see Figure
36, page 17). Do not remove adjustment screw.
• see Troubleshooting, page 20
Pilot Burner
Ignitor
Figure 37 - Pilot
Figure 38 - Correct Pilot Flame Pattern
BURNER FLAME PATTERN
Burner flames will be steady, not lifting or floating. Flames should go
up through the middle of log set. Flames should not "spill" to edges
of pan or sides of log set.
Figure 39 shows a typical flame pattern. If burner flame pattern differs
from that described:
• turn appliance off (see To Turn Off Gas to Appliance, page 17)
• see Troubleshooting, page 20
Figure 39 - Typical Flame Pattern
18
Thermopile
Thermopile
Pilot Burner
Ignitor
SuperiorFireplaces.US.com

CLEANING AND MAINTENANCE

WARNING: Installation and repair should be done
by a qualified service person. The appliance should
be inspected before each use and at least annually
by a qualified service person. More frequent cleaning
may be required due to excessive lint from carpeting,
bedding material, pet hair, etc. It is imperative that
the control compartments, burners and circulating air
system be kept clean.
WARNING: The logs can be hot. Handle only when
cool.
WARNING: Turn off gas and electrical power before
servicing appliance.
WARNING: Failure to keep the primary air
opening(s) of the burner(s) clean may result in sooting
and property damage.
PILOT AND BURNER
• Remove logs and ember material before cleaning burner and replace
when cleaning is complete.
• Burner and controls should be cleaned with compressed air to
remove dust, dirt or lint.
• Use a vacuum cleaner or small, soft bristled brush to remove excess
dust, dirt or lint.
LOGS
• If you remove logs for cleaning, refer to log placement information
on page 12 to properly replace logs.
• Use a vacuum cleaner to remove any carbon buildup on logs.
• Replace log(s) if broken. See Replacement Parts, page 28.
• Replace ember material periodically as needed. See Replacement Parts,
page 28.