WARNING: Turn off appliance and
let cool before cleaning.
CAUTION: You must keep control
areas, burner and circulating air pas-
sageways of heater clean. Inspect these
areas of heater before each use. Have
heater inspected yearly by a qualifi ed
service person. Heater may need more
frequent cleaning due to excessive lint
from carpeting, bedding material, pet
hair, etc.
WARNING: Failure to keep the
primary air opening(s) of the burner(s)
clean may result in sooting and prop-
erty damage.
Perform a periodic visual check of
pilot and burner fl ame.
BURNER INJECTOR HOLDER AND PILOT
AIR INLET HOLE
The primary air inlet holes allow the proper amount
of air to mix with the gas. This provides a clean burn-
ing fl ame. Keep these holes clear of dust, dirt, lint,
and pet hair. Clean these air inlet holes prior to each
heating season. Blocked air holes will create soot.
We recommend that you clean the unit every three
months during operation and have heater inspected
yearly by a qualifi ed service person.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust and
dirt. To clean these parts we recommend using
compressed air no greater than 30 PSI. Your local
computer store, hardware store, or home center
may carry compressed air in a can. If using com-
pressed air in a can, please follow the directions on
the can. If you don't follow directions on the can,
you could damage the pilot assembly.
1. Shut off unit, including pilot. Allow unit to cool
for at least thirty minutes.
2. Inspect burner, pilot, and primary air inlet holes
on injector holder for dust and dirt (see Figure
50).
3. Blow air through the ports/slots and holes in
the burner.
900719-00D

CLEANING AND MAINTENANCE

4. Check the injector holder located at the end of the
5. Blow air into the primary air holes on the injec-
6. In case any large clumps of dust have now been
Clean pilot assembly also. A yellow tip on the pilot
fl ame indicates dust and dirt in the pilot assembly.
There is a small pilot air inlet hole about 2" from
where the pilot fl ame comes out of the pilot as-
sembly (see Figure 51). With unit off, lightly blow
air through the air inlet hole. You may blow through
a drinking straw if compressed air is not available.
SuperiorFireplaces.us.com
burner tube again. Remove any large particles
of dust, dirt, lint, or pet hair with a soft cloth or
vacuum cleaner nozzle.
tor holder.
pushed into the burner repeat steps 3 and 4.
Ports/Slots
Burner Tube
Primary Air
Inlet Holes
Figure 50 - Injector Holder On Outlet Burner
Tube
Figure 51 - Pilot Inlet Air Hole (Your pilot may
vary from pilot shown)
Injector
Holder
Pilot Air Inlet
Hole
Pilot Assembly