NOTICE: This appliance is intended
for supplemental heating. Use this
heater along with your primary heat-
ing system. Do not install this heater
as your primary heat source. If you
have a central heating system, you
may run system's circulating blower
while using heater. This will help cir-
culate the heat throughout the house.
In the event of a power outage, you
can use this heater as your primary
heat source.
WARNING: A qualifi ed service
person must install fi replace. Follow
all local codes.
WARNING: Never install the
fi replace
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, cloth-
ing, or other fl ammable objects
are less than 36" from the front
and 42" from the top of fi replace.
For side clearances see Figure 8,
Page 11
• in high traffi c areas
• in windy or drafty areas
CAUTION: This fi replace creates
warm air currents. These currents
move heat to wall surfaces next to
fi replace. Installing fi replace next
to vinyl or cloth wall coverings or
operating heater where impurities
(such as, but not limited, to tobacco
smoke, aromatic candles, cleaning
fl uids, oil or kerosene lamps, etc.)
in the air exist, may discolor walls
or cause odors.
900719-00D

INSTALLATION

NOTE: Your fi replace is designed to be used in zero
clearance installations. Wall or framing material
can be placed directly against any exterior surface
on the rear, sides, or top of your fi replace, except
where standoff spacers are integrally attached.
Where standoff spacers are attached to your
fi replace, combustible material (studs and wall
board) may be place on top and above the top of
the standoffs.
Use the dimensions shown for rough openings to
create the easiest installation. See Built-In Fireplace
Installation, Page 12.
IMPORTANT: Vent-free heaters add moisture to the
air. Although this is benefi cial, installing fi replace
in rooms without enough ventilation air may cause
mildew to form from too much moisture. See Air
for Combustion and Ventilation, Page 6.
IMPORTANT: Make sure the fi replace is level. If fi re-
place is not level, log set will not work properly.
CHECK GAS TYPE
Use the correct type of gas (natural or propane/LP).
If your gas supply is not the correct gas type, do not
install appliance. Call dealer where you purchased
the appliance for proper type appliance.
WARNING: This appliance is equipped
for either natural gas or propane/LP gas but
not both. Gas type is indicated on the rating
plate. Field conversion is not permitted.