Superior Fireplaces VRT3132WS Assembly, Installation And Operation Instructions

Universal vent-free firebox

Advertisement

P900849-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
In the Commonwealth of Massachusetts:
Installation must be performed by a licensed plumber or
gas fitter;
• See Table of Contents for location of additional Common-
wealth of Massachusetts requirements.
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal injury
or loss of life.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammables or liquids in the vicinity of
this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call
the fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
C
US
Report No. F14-168
INSTALLATION AND
OPERATION INSTRUCTIONS
UNIVERSAL VENT-FREE FIREBOX
32" x 24", 36" x 24", & 42" x 24" Universal Vent-Free Fireboxes
P/N 900849-00 REV. B 09/2017
MODELS
VRT3132WS
VRT3132F
VRT3136F
VRT3142WS
FOR USE ONLY WITH A LISTED GAS-FIRED
UNVENTED DECORATIVE ROOM HEATER NOT TO
EXCEED 40,000 BTU/H.
DO NOT BUILD A WOOD FIRE.
WARNING: IMPROPER INSTALLATION, ADJUST-
MENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE INJURY OR PROPERTY DAMAGE.
REFER TO THIS MANUAL. FOR ASSISTANCE OR
ADDITIONAL INFORMATION CONSULT A QUALI-
FIED INSTALLER, SERVICE AGENCY OR THE GAS
SUPPLIER.
Carefully review the instructions supplied with
the decorative type unvented room heater for the
minimum fireplace size requirement.
DO NOT INSTALL AN APPLIANCE IN THIS FIREBOX
UNLESS THIS FIREBOX MEETS THE MINIMUM
DIMENSIONS REQUIRED FOR THE INSTALLATIONS.
THIS IS A VENT-FREE GAS-FIRED HEATER ENCLO-
SURE. IT USES AIR (OXYGEN) FROM THE ROOM
IN WHICH IT IS INSTALLED. PROVISIONS FOR
ADEQUATE COMBUSTION AND VENTILATION AIR
MUST BE PROVIDED. REFER TO COMBUSTION
AND VENTILATION AIR SECTION, PAGE 4.
Due to high temperatures, the appliance should be located out
of traffic and away from furniture or draperies.
Do not place clothing or other materials on or near this appliance.
IMPORTANT: READ AND UNDERSTAND THESE INSTRUCTIONS
COMPLETELY BEFORE INSTALLING YOUR VENT-FREE ROOM
HEATERS.
VRT3136WS
VRT3142F

Advertisement

Table of Contents
loading

Summary of Contents for Superior Fireplaces VRT3132WS

  • Page 1 INSTALLATION AND OPERATION INSTRUCTIONS UNIVERSAL VENT-FREE FIREBOX 32" x 24", 36" x 24", & 42" x 24" Universal Vent-Free Fireboxes P/N 900849-00 REV. B 09/2017 MODELS VRT3132WS VRT3132F VRT3136WS VRT3136F VRT3142WS VRT3142F P900849-00 FOR USE ONLY WITH A LISTED GAS-FIRED INSTALLER: Leave this manual with the appliance.
  • Page 2: Important Safety Information

    IMPORTANT SAFETY WARNING WARNING INFORMATION Carbon Monoxide Poisoning: Early • The heater must be isolated from INSTALLER: PLEASE LEAVE THESE INSTRUC- signs of carbon monoxide poisoning the gas supply piping system by TIONS WITH THE OWNER. closing its individual manual are similar to the flu with head- OWNER: PLEASE RETAIN THESE INSTRUC- shut-off valve during any pres-...
  • Page 3: Table Of Contents

    CONGRATULATIONS! Misc. Codes / Standards The Installation must conform to local codes or, In selecting this Superior ® Vent-Free Gas Firebox you have chosen the finest and most dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a wood in the absence of local codes, with the National burning fireplace.
  • Page 4: Combustion And Ventilation Air

    COMBUSTION AND VENTILATION AIR 2. Divide the volume of space by 50 ft Your options are: determine the maximum BTU/Hr the space can support. Heaters installed in these appliances shall a. Rework equations adding the space of adjoin- not be installed in a confined space. Heaters ing room(s).
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    NOTE: The following requirements reference LOCATION OF FIREBOX WARNING various Massachusetts and national codes Carefully select the best location for installation not contained in this document. Do not install these built-in Vent- of your built-in Vent-Free firebox. The following factors should be taken into consideration: Free fireboxes in sleeping quarters, or in recreational vehicles.
  • Page 6: Clearances

    Clearances Ceiling clearance: The ceiling must be at least 40" from the top of the firebox opening (Figure 2). Ensure the minimum clearances shown in Figures 2 through 4 are maintained. Left and right clearances are determined when facing the Noncombustible material: Noncombustible materials, such as slate and front of the firebox.
  • Page 7 Noncombustible material (minimum requirements) with wood mantel Combustible Mantel and Trim Clearance or other combustible projections: To install the firebox with a wood mantel, shelf or other combustible projection above firebox opening. VRT3100 Series Models WITH Hood Installed Refer to Figure 4. Hood is required on all installations for these models.
  • Page 8: Assembly Steps

    ASSEMBLY STEPS Consult all local codes. IMPORTANT NOTES: Properly size and route the gas supply line Hold heater regulator with a wrench • Illustrations shown in this manual reflect from the supply regulator to the area where the to prevent movement when connect- “typical”...
  • Page 9: Firebox Framing

    Firebox Framing 3. Note the floor construction, i.e. 2" x 6", 2" x NOTE: The nailing flange and the area directly 8" or 2" x 10", single or double joists, type behind the nailing flange is exempt from the clearances described on the firebox clearance and thickness of floor boards.
  • Page 10: Specifications

    SPECIFICATIONS Fireplace Dimensions Model No. VRT3132WS 37-3/4 37-1/4 19-1/2 7-3/8 15-7/8 7-1/2 1-3/8 5-1/2 30-3/8 29-5/8 VRT3132F (839) (610) (956) (947) (496) (508) (77) (188) (404) (191) (305) (35) (140) (772) (753) VRT3136WS 41-3/4 37-1/4 23-1/2 7-3/8 15-7/8 7-1/2 1-3/8...
  • Page 11: Framing Specifications

    FRAMING SPECIFICATIONS Corner Installation Framing Dimensions Back Wall Of Chase/Enclosure This Figure corresponds to Table 1 Opening VRT3132WS VRT3136WS VRT3142WS Including Finishing Materials If Any VRT3132F VRT3136F VRT3142F 38-1/4 (972) 42-1/4 (1073) 48-1/4 (1226) 40-1/4 (1022) 40-1/4 (1022) 40-1/4 (1022)
  • Page 12: Optional Equipment / Blower Kit Installation

    IMPORTANT Top View * Junction Box * Electrical Outlet The Ground Lead must be connected to the green screw (located on the Hood junction box). Failure to do this Blower could result in an electrical short or Bend blower mounting shock injury.
  • Page 13 Installation Instructions - Cover Plate FBK-100 or FBK-200 Blower Kits and JBK Junction Box Kit J-Box and Receptacle IMPORTANT Remove knock-out All electrical wiring must be performed by licensed Elec- (strain relief bush- tricians. Electrical wiring must comply with the National ing [not supplied] presses into this Electrical Code ANSI/ NFPA 70 - latest edition...
  • Page 14 Step 8. Ensure that power supply wires are NOT "live" before making these connections). Install J-Box Cover Plate as follows: Feed the * Romex wires (or other equivalent plastic insulated wire - Refer ANSI/NFPA 70 - National Electrical Code - Latest Firebox Edition) through the J-Box Cover rectangular opening, then con- floor...
  • Page 15: Firebox Finishes

    FIREBOX FINISHES and wall surrounds to prevent air intrusion. Use noncombustible caulking material only to seal the black metal facing to the surround material on the finished wall. See Figures 3 and 23. There are a wide variety of “finished looks” for your built-in Vent-Free firebox from formal wall decor with elaborate mantels to rustic wood Raised Hearth Extension paneling or warm brick facings.
  • Page 16 (ref. Form #750206M) Cat. No. Model Where Used The ON/OFF wall switch kit F3361 ASD3224-TI VRT3132WS, VRT3132F Outside Air Gate and Duct Kit may be used to control the H1959 ASD3624-TI VRT3136WS, VRT3136F blower operation, if FBK- These kits have an air gate assembly, 4" diameter 100 blower kit is installed.
  • Page 17: Replacement Parts List

    2. The *serial number of the firebox. 3. The part number. damage or personal injury. 4. The description of the part. 5. The quantity required. 6. The installation date of the firebox. VRT3132WS VRT3136WS VRT3142WS VRT3132F VRT3136F VRT3142F Cat. # F3305 Cat.
  • Page 18 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...
  • Page 19: Warranty

    Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts ® 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior Brand gas fi replace, Stove or Insert ("Product") to be free from defects in materials ®...
  • Page 20 IHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and the discontinuance of colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2017 Innovative Hearth Products P/N 900849-00 REV.

This manual is also suitable for:

Vrt3132fVrt3136wsVrt3136fVrt3142wsVrt3142f

Table of Contents