Specifications - Lennox G32V Series Service Literature

Hide thumbs Also See for G32V Series:
Table of Contents

Advertisement

Model No.
Input Btuh (kW) − High
Input Btuh (kW) − Low
Output Btuh (kW) − High
Output Btuh (kW) − Low
A.F.U.E.
California Seasonal Efficiency
Exhaust pipe connection (PVC) diameter
Intake pipe connection (PVC) diameter
Condensate drain connection (PVC)
_F (_C)
_F (_C)
Temperature rise range
Temperature rise range
High static certified by (A.G.A./C.G.A.)
Gas Piping Size I.P.S. − Natural − in. (mm)
Blower wheel nominal diameter x width − in. (mm)
Blower motor output
hp (W)
Nominal cooling that can be added − Tons (kW)
No. & size of filters − in. (mm)
Shipping weight
lbs. (kg) 1 package
Electrical characteristics
Concentric Vent/Intake Air/Roof Termination Kit
Vent/Intake Air Roof
Vent/Intake Air Roof
Termination Kit
vent size
Vent/Intake Air Wall
Termination Kit
Termination Kit
vent size
vent size
Condensate Drain Heat Cable
Heat Cable Tape
Heat Cable Tape
L.P. Kit
Annual Fuel Utilization Efficiency based on U.S. DOE test procedures and FTC labeling regulations. Isolated combustion system rating for non−weatherized furnaces.
Meets California Nitrogen Oxides (NO
Determine from venting tables proper intake and exhaust pipe size and termination kit required.
Polyurethane frame type filter.
NOTE − 2 inch x 3 inch (51 mm x 76 mm) adaptor is furnished with −100 and −125 furnaces for exhaust pipe connection.

SPECIFICATIONS

in. (mm)
in. (mm)
in. (mm)
Low Fire
High Fire
in. wg. (Pa)
OPTIONAL ACCESSORIES (Must Be Ordered Extra)
2 inch (51 mm)
3 inch (76 mm)
2 inch (51 mm)
3 inch (76 mm)
Fiberglass − 1/2 in. (38 mm)
Aluminum foil − 2 in. (25 mm)
) Standard and California Seasonal Efficiency requirements.
x
G32V3−75
75,000 (22.0)
51,000 (14.9)
67,500 (19.8)
45,900 (13.4)
92.7%
89.4%
2 (51)
30 − 60(16 − 33)
40 − 70 (22 − 39)
10 x 8 (254 x 203)
1/2
2 to 3 (7 to 10.6)
(1) 14 x 25 x 1 (356 x 635 x 25)
161 (73)
120 volts
60 hertz
60G77
1/1/2 inch (38 mm)
15F74 (ring kit)
22G44 (close couple)
30G79 (WTKX close couple with extension riser)
44J40 (close couple)
26K68 6 ft. (1.8 m) − 26K69 24 ft. (7.3 m) − 26K70 50 ft. (15.2 m)
34L29 (−1, −2 models) 11M55 (−3 and later models)
Page 3
G32V5−100
G32V5−125
100,000 (29.3)
125,000 (36.6)
68,000 (19.9)
85,000 (24.9)
90,000 (26.4)
112,500 (32.9)
61,200 (17.9)
76,500 (22.4)
93.2%
94.2%
90.1%
91.1%
2 (51)
3 (76)
1/2 (12.7)
35 − 65 (19 − 36)
50 − 80 (28 − 44)
.80 (200)
1/2 (12.7)
11−1/2 x 9 (292 x 229)
1
3−1/2 to 5 (12.3 to 17.6)
(1) 20 x 25 x 1 (508 x 635 x 25)
201 (91)
221 (100)
1 phase (less than 12 amps)
33K97
2 inch
33K97− 2 inch (51 mm)
(51 mm)
60L46 − 3 inch (76 mm)
15F75
44J41
30G28 (WTK close couple)
81J20 (WTK close couple)
39G04
39G03