Vsp2−1 - Lennox G32V Series Service Literature

Hide thumbs Also See for G32V Series:
Table of Contents

Advertisement

TWO−STAGE CONTROL BOARD
W2 TIMED ON
DELAY JUMPER
MODE OF
OPERATION
JUMPER
FIGURE 10
HIGH SPEED
SELECTOR PINS
(COOLING ONLY)
LOW SPEED
SELECTOR PINS
(COOLING, HEATING and
CONTINUOUS FAN)
HEATING STAGE
JUMPER SELECTOR PINS
JP73
15 PIN PLUG
(BOARD TO VARIOUS
POINTS IN FURNACE)
VSP2−1 VARIABLE SPEED CONTROL BOARD SELECTIONS
1
JP2
HIGH
LOW
1
2
3
4
HTG.
BLOWER
1
2
JP1
1
6.VSP2−1 Blower Control Board (A24)
G32V −1 / −3 units
G32V units are equipped with a variable speed motor that is
capable of maintaining a specified CFM throughout the ex-
ternal static range. The unit uses the VSP2−1 variable
speed control board, located in the blower compartment,
which controls the blower speed and provides diagnostic
LEDs. The control has both a non−adjustable, factory preset
ON" fan timing delay and an adjustable OFF" fan timing delay
(see figure 13).
The VSP2−1 also senses limit trip condition and turns on the
blower. The G32V limit switch is located in the middle of the
vestibule wall. When excess heat is sensed in the heat ex-
changer, the limit switch will open and interrupt the current
to the gas valve, while at the same time the VSP2−1 energizes
the blower on heating speed. The limit automatically resets
when the unit temperature returns to normal and the blower is
de−energized.
Diagnostic LEDs located on the VSP2−1 control board are pro-
vided to aid in identifying the unit's mode of operation. Certain
scenarios will arise depending on the jumper positions. Refer
to figure 11 for identification.
ADJUST
HEAT
1
TEST
2
3
+
4
NORM
HEAT
DS3
HI/LOW
DS2
ON/OFF
DS1
210
150
FIGURE 11
Page 14
JP46
13 PIN PLUG
(BOARD TO MOTOR)
HEATING SPEED
1
SELECTOR PINS
2
See table 11 for VSP2
3
factory settings
4
DS4
OPERATIONAL
SELECTOR PINS
(Affects both heating
CFM
and cooling modes)
DIAGNOSTIC
FAN OFF"
TIMING PINS
DS LEDS