SP ECIF ICATIONS
Gas
Heating
Performance
High
Fire
Low
Fire
High static - in. w.g.
Connections
in.
Condensate Drain Trap (PVC pipe) - i.d.
with field supplied (PVC coupling) - o.d.
Indoor
Wheel nominal diameter x width - in.
Blower
Electrical Data
Shipping Data
NOTE - Filters and provisions for mounting are not furnished and must be field provided.
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized
1
furnaces.
S PECIF ICATIONS
Gas
Heating
Performance
High
Fire
Low
Fire
High static - in. w.g.
Connections
in.
Condensate Drain Trap (PVC pipe) - i.d.
with field supplied (PVC coupling) - o.d.
Indoor
Wheel nominal diameter x width - in.
Blower
Electrical Data
Shipping Data
NOTE - Filters and provisions for mounting are not furnished and must be field provided.
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized
1
furnaces.
Model No.
AFUE
1
Input - Btuh
Output - Btuh
Temperature rise range - °F
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
Input - Btuh
Output - Btuh
Temperature rise range - °F
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
Heating
Cooling
Intake / Exhaust Pipe (PVC)
Gas pipe size IPS
with furnished 90° street elbow
Motor output - hp
Tons of add-on cooling
Air Volume Range - cfm
Voltage
Blower motor full load amps
Maximum overcurrent protection
lbs. - 1 package
Model No.
AHRI Ref. No.
AFUE
1
Input - Btuh
Output - Btuh
Temperature rise range - °F
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
Input - Btuh
Output - Btuh
Temperature rise range - °F
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
Heating
Cooling
Intake / Exhaust Pipe (PVC)
Gas pipe size IPS
with furnished 90° street elbow
Motor output - hp
Tons of add-on cooling
Air Volume Range - cfm
Voltage
Blower motor full load amps
Maximum overcurrent protection
lbs. - 1 package
EL297UH045XV36B
97%
44,000
43,000
35 - 65
3.5 / 10.0
29,000
28,000
20 - 50
1.7 / 4.5
0.8
1.0
2 / 2
1/2
3/4
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 MPT
10 x 9
1/2
2 - 3
465 - 1370
120 volts - 60 hertz - 1 phase
7.7
15
130
EL297UH090XV48C
4988513
97%
88,000
86,000
45 - 75
3.5 / 10.0
57,000
56,000
30 - 60
1.7 / 4.5
0.8
1.0
2 / 2
1/2
3/4
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 MPT
11 x 11
3/4
2.5 - 4
680 - 1770
120 volts - 60 hertz - 1 phase
10.1
15
163
Page 2
EL297UH070XV36B
EL297UH090XV36C
97%
66,000
64,000
50 - 80
3.5 / 10.0
43,000
42,000
25 - 55
1.7 / 4.5
0.8
1.0
2 / 2
1/2
3/4
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 MPT
3/4 slip x 3/4 MPT
10 x 9
1/2
2 - 3
490 - 1365
7.7
15
136
EL297UH090XV60C
EL297UH110XV48C
4988514
97%
88,000
86,000
40 - 70
3.5 / 10.0
57,000
56,000
25 - 55
1.7 / 4.5
0.8
1.0
2 / 2
1/2
3/4
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 MPT
3/4 slip x 3/4 MPT
11 x 11
1
3 - 5
840 - 2195
12.8
20
164
97%
88,000
85,000
60 - 90
3.5 / 10.0
57,000
56,000
30 - 60
1.7 / 4.5
0.8
1.0
2 / 2
1/2
3/4
10 x 9
1/2
2 - 3
520 - 1360
7.7
15
152
4988515
97%
110,000
106,000
60 - 90
3.5 / 10.0
72,000
70,000
35 - 65
1.7 / 4.5
0.8
1.0
2 / 2
1/2
3/4
11 x 11
3/4
2.5 - 4
670 - 1760
10.1
15
173

Hide quick links: