G32V−1 / −3 OPERATION SEQUENCE AND JUMPERS SUMMARY WITH VSP2 (COOLING CONTINUED)
T−STRIP JUMPER
MATCH UP
FOR HEATING JUMPERS
SEE SEE HEATING SECTION
ABOVE
Harmony and Single-
Speed Compressor
Harmony and Two-
Speed Compressor
COMMENTS OR SEQUENCE
Remove pin #3 of the J73
terminal on the VSP con-
No Jumpers
trol. Insulate end to pre-
(Remove
vent shorting. Blower oper-
jumper from
ates on PWM signal gener-
Y1 to DS").
ated by Harmony. Harmony
overrides blower speed
taps. Blower speed varies
according to zone demand.
Remove pin #3 of the J73
No Jumpers
terminal on the VSP con-
(Remove
trol. Insulate end to pre-
jumper from
vent shorting. Blower oper-
Y1 to DS").
ates on PWM signal gener-
ated by Harmony. Harmony
overrides blower speed
taps. Blower speed varies
according to zone demand.