Lennox G32V Series Service Literature page 72

Hide thumbs Also See for G32V Series:
Table of Contents

Advertisement

(continued from previous page)
G32V−1 / −3 OPERATION SEQUENCE AND JUMPERS SUMMARY WITH VSP2 (COOLING CONTINUED)
MATCH UP
T−STRIP JUMPER
FOR HEATING JUMPERS
SEE HEATING SECTION
ABOVE
No Jumpers
CCB1 with Single-Speed
(Remove jumper
Compressor, no Harmony
from Y1 to DS")
CCB1 with Two-Speed
No Jumpers
Compressor, no Harmony
(Remove jumper
from Y1 to DS")
(continued on following page)
COMMENTS OR SEQUENCE
Blower speed is controlled by
the DC signal from CCB1.
Blower operates on low speed
heat/cool tap during dehumidifi-
cation. Otherwise, blower oper-
ates on high speed cool tap
during cooling cycle.
Blower speed is controlled by
the DC signal from CCB1.
Blower operates on low speed
heat/cool tap during dehumidi-
fication. Otherwise, blower op-
erates on high speed cool tap
during high speed compressor
operation and low speed heat/
cool tap during low speed
compressor operation.
Y1
Y2

Hide quick links: