The second production area with office as well as the outside storage area are supplied by a
SCALANCE XP208 PoE
are the same: An access point has the purpose of making access to the company network
possible, for example, to query logistics and job data. In addition to this and IP camera will
monitor the entire area. In production, a SCALANCE W788
this use case due to the high data transmission rate of up to 450 Mbps and its robust design.
The SCALANCE W786
condensation and salt spray and is therefore designed for use outdoors without additional
measures. Only one Ethernet cable needs to be laid in the outside storage area; the access
point and the camera are connected to the network via a SCALANCE X108PoE
Benefits
● Problem-free integration of the SCALANCE X devices due to the availability of port
modules for all common transmission media
● Minimum cabling effort due to Power over Ethernet. All the devices in production and
outside storage are supplied with power via the Ethernet cable
● Simple expansion of the entire system through the high port density of the SCALANCE X
devices
3.10

Connecting a PROFIBUS network to a PROFINET installation

Task
In a brickworks, raw bricks are transported to the drying kiln by a shuttle conveyor
functions of the shuttle conveyor are controlled by an S7-1200 that is equipped with a CM
1243-5 communication module. The movements of the shuttle conveyor are synchronized
with the production process in the stationary parts of the works with which the conveyor
communicates via a wireless PROFIBUS modem
automatically when the conveyor arrives and close again automatically. The original solution
included a wireless PROFIBUS modem
stations
This solution alone eliminated numerous problems that occurred previously with the trailing
cables but nevertheless there were occasional short interruptions in communication. The
reason was that the transmission speed of the wireless PROFIBUS communication was not
fast enough for this situation.
Industrial Ethernet
System Manual, 09/2019, C79000-G8976-C242-10
3.10 Connecting a PROFIBUS network to a PROFINET installation
. Both in the production and in the storage area the requirements
installed in the outside storage area is resistant to UV radiation,
required for production.
will be used that is ideal for
. The doors of the drying kiln open
and the ET 200 I/O
Examples of applications
.
. The