Interfaces - Siemens SIMATIC NET System Manual

Industrial ethernet / profinet industrial ethernet
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

On site display (Set button)
C-PLUG slot
● Suitable / available or according to the specified standard.
Functions
The following table indicates the functions provided by the individual devices:
Configuration with WBM, CLI or SNMP
MIB support
HTTP
SNMPv1, SNMPv2 and SNMPv3
SysLog
DHCP client
DHCP server (internal network)
Static IP routing
NAT/NAPT
Firewall (Stateful Packet Inspection)
Max. firewall data throughput
IPsec support
Max. number of VPN connections
Max VPN data throughput
Softnet security client
Connection to SINEMA Remote Connect via VPN
● Suitable / available or according to the specified standard.
4.8.5

Interfaces

The SCALANCE S modules have the following connectors or interfaces:
Device
Total number of
available ports
S615
SC632-2C
2
SC636-2C
6
SC642-2C
2
SC646-2C
6
Of which 2 are combo ports
1)
Industrial Ethernet
System Manual, 09/2019, C79000-G8976-C242-10
Twisted pair
10/100 Mbps
5
5x RJ45
-
1)
-
1)
-
1)
-
1)
4.8 SCALANCE S Industrial Security Appliance
S615
SC632-2C
S615
SC632-2C
100 Mbps
600 Mbps
-
20
-
35 Mbps
-
Fiber-optic cables
10/100/1000 Mbps
1000 Mbps
-
Max. 2x RJ45
Max. 6x RJ45
Max. 2x RJ45
Max. 6x RJ45
SCALANCE network components
SC636-2C
SC642-2C
SC636-2C
SC642-2C
600 Mbps
600 Mbps
-
-
200
-
120 Mbps
Combo ports
100/1000 Mbps
-
-
-
2x SFP
-
2x SFP
-
2x SFP
-
2x SFP
SC646-2C
SC646-2C
600 Mbps
200
120 Mbps
267