Epson ColorWorks C6500Au Technical Reference Manual page 91

Hide thumbs Also See for ColorWorks C6500Au:
Table of Contents

Advertisement

2
Make the settings for the barcode type you selected.
• Settings for PDF417
∗ Module Width:
∗ Module Height:
∗ Column:
∗ Row:
∗ Truncation Symbol:
∗ Error Correction Level
• Settings for MicroPDF417
∗ Module Width:
∗ Module Height:
∗ Column:
∗ Row:
• Settings for QR code
∗ Model:
∗ Module:
∗ Error Correction Level:
∗ Character Mode:
• Settings for Micro QR code
∗ Version:
∗ Module:
∗ Error Correction Level:
• Settings for MaxiCode
∗ Mode:
• Settings for GS1 DataBar
∗ Module:
∗ Number of Characters: Specify the max width of GS1 DataBar.
Set module width of PDF417.
For the recommended value, see
Specify the ratio of PDF417 module height to the module width.
For the recommended value, see
Specify the number of columns of PDF417.
Specify the number of rows of PDF417.
Select the check box to create a symbol using data excluding the stop code of
PDF417.
Specify an error correction level for PDF417. This allows the symbol data to be
correctly read even if a portion of the symbol is missing or damaged. The larger
the number is, the higher the possibility of data restoration gets.
Set module width of MicroPDF417.
For the recommended value, see
Specify the ratio of MicroPDF417 module height to the module width.
For the recommended value, see
Specify the number of columns of MicroPDF417.
Specify the number of rows of MicroPDF417.
Select a QR code model.
Select a width of a cell (module) of QR code.
For the recommended value, see
Specify an error correction level for QR code. This allows the symbol data to be
correctly read even if a portion of the symbol is missing or damaged. The possi-
bility of data restoration gets higher in the order of L, M, Q, and H.
Select a mode for data to be converted into a QR code.
Specify the version of Micro QR code.
Select a width of a cell (module) of Micro QR code.
For the recommended value, see
Specify an error correction level for Micro QR code. This allows the symbol data
to be correctly read even if a portion of the symbol is missing or damaged. The
possibility of data restoration gets higher in the order of L, M.
Select a mode of MaxiCode.
Set module width of GS1 DataBar.
For the recommended value, see
Set this if you have selected GS1 DataBar Expanded Stacked.
"Recommended Module Values" on page 93.
"Recommended Module Values" on page 93.
"Recommended Module Values" on page 93.
"Recommended Module Values" on page 93.
"Recommended Module Values" on page
"Recommended Module Values" on page
"Recommended Module Values" on page
Chapter3 Handling
93.
93.
93.
91

Hide quick links:

Advertisement

Table of Contents
loading