Step 4: Installing
Anti-Tip
Device
PD30 and PD36
Duel Fuem Ranges
(Figures
8A and 8B)
Thermador
Serv{ce
Part No.
Qty
415078
4
487310
1
Description
Screw, Phillips, #10 x 1=1/2"
Anti=Tip Bracket, Floor=Mounted
{MPORTANT
_NSTALLAT_ON
{NFORMAT_ON:
o
The anti-tip
bracket
may be attached
to a solid
wood cabinet having a minimum wall thickness of 3/
,,
.
The thickness of the wall or floor may require use
of longer screws, available at your local hardware
store.
.
In all cases, at least two (2) of the bracket mounting
screws must be fastened to solid wood or metal.
o
Use appropriate anchors when fastening the mount-
ing bracket to any material other than hardwood or
metal.
.
Prepare
holes at fastener
locations
as identified
below:
For walls, wall studs, or floors_osed
of solid wood or metal, drill I/8" pilot holes.
O
O
O
O
Figure
8A - Mounting
Anti-tip
Bracket
For walls
or floors
composed
of dr_
_ther
soft materials, drill 3/16"
holes to a minimum depth of 1=3/4", then tap
plastic anchors into each of the holes using a
hammer.
For walls or floors com#osed
of concrete or
, drill 3/16" holes to a minimum
depth of 1=3/4", then tap concrete
anchors
into each of the holes using a hammer.
For walls or floors having ceramic tile cover=
m__, drill 3/I6" holes through the tile only, then
drill into the material behind the tile as indi-
cated immediately
above.
If the range is moved to a new location, the Anti-
Tip Device must be removed and reinstalled.
MOUNTING
ANT_-T_P
BRACKET
The alternative
floor mounted bracket shall be installed
as follows:
a)
Place bracket on floor in position shown in Figure
8B.
b)
Secure
to floor or wall stud.
c)
Later, when the unit is installed,the
adjustable
leg
will slide under the bracket.
Figure 8B
- Placement
of Anti-tip
Bracket
(TopView)
Cabinet
Wall Line
Floor
./
/
\--
If< 2=i,,'z'
Front
Edge of I
(typ ca
=
Right Cabinet
I
either side)
:_J 2ol/2" _( from edge of range
\
12

Advertisement

loading

This manual is also suitable for:

Pd304Pd48Pd36Lb36rPd484ggePd364gl ... Show all