13. Once you set the adjust lever to your target position, push both edges of the head
fixing plate 2 or 3 times by your fingers.
Head fixing plate
Push both edges.
Figure 5-19. Pushing the Head Fixing Plate
14. Tighten a screw securing head fixing plate in the right side of the carriage unit.
15. Then install all ink cartridges.
16. Select "Return the carriage to the home position", and then OK button.
Figure 5-20. Head Angular Adjustment Mode 2
ADJUSTMENT
17. Press ink button to perform ink cartridge replacement cleaning. After completing
the cleaning, the next head angle check pattern will automatically be printed. The
program screen returns to the Figure 5-13 automatically.
18. If you judge that the adjustment is required one more time, select "Move the
carriage to the adjustment position" and press OK button to change head
adjustment lever position again. The program screen advances to Figure 5-15.
19. Repeat from step 8 to step 18 unti you can judge the head angle condition is in
right. Once you complete the adjustment, select "no need to adjust" on Figure 5-13
screen to advance to the I-D adjustment.