19.4.2 Setting the distance of the transport clamps to the folder sole
Fig. 131: Setting the distance of the transport clamps to the folder sole (1)
(1) - Transport clamp
Proper setting
There must be a specific distance between the outer edges of the folder
sole (2) and the inner edges of the transport clamps (1). The distance for
moderately heavy sewing material should be approx. 1.0 mm to 1.5 mm.
This distance is necessary to ensure both uniform piping widths and
unhindered transport of the sewing material.
To set the distance between the folder sole and the transport clamps:
1. Open the menu Program parameters > Process of transport
2. Open the menu Service > Machine config. > Transport
3. Pull the transport carriage to the front by hand.
130
(motorized)
①
clamp > Select piping type and set all values to 0 ( p. 335).
clamp adjustment and press the
②
①
(2) - Folder sole
button.
Service Instructions 755 A/756 A - 00.0 - 02/2019
Transport clamps