Error code
Symbol
4683
Error code 5000-5999: Error messages machine configuration
5108
5201
5202
5203
5204
5205
5206
5209
5210
460
Meaning
No valid sequence number
-
Error step motor corner knife,
slanted seam end
Error step motor corner knife,
slanted seam beginning
Error step motor corner knife,
angle seam begin right
Error step motor corner knife,
angle seam begin left
Error step motor corner knife,
angle seam end right
Error step motor corner knife,
angle seam end left
Error horizontal step motor mark-
ing lamp
Error vertical step motor marking
lamp
Troubleshooting
Remedial action
• Check communication
• Change sequence
• Compare software version of DAC
and OP7000
Use USB file from this machine.
• Check cable to reference switch
• Check reference switch
• Check motor for stiff movement
• Check cable to reference switch
• Check reference switch
• Check motor for stiff movement
• Check cable to reference switch
• Check reference switch
• Check motor for stiff movement
• Check cable to reference switch
• Check reference switch
• Check motor for stiff movement
• Check cable to reference switch
• Check reference switch
• Check motor for stiff movement
• Check cable to reference switch
• Check reference switch
• Check motor for stiff movement
• Check cable to reference switch
• Check reference switch
• Check motor for stiff movement
• Check cable to reference switch
• Check reference switch
• Check motor for stiff movement
Service Instructions 755 A/756 A - 00.0 - 02/2019