Troubleshooting - Ricoh CH-C1 Technical Bulletin

Hide thumbs Also See for CH-C1:
Table of Contents

Advertisement

Model: CH-C1
Subject:
New brackets to prevent JAM18
From:
1st MFP Tech Service Sec., MFP Tech Service Dept.,
Classification:
SYMPTOM
JAM18 (Main Relay Sensor: Late Jam) may occur.
CAUSE
Machine internal pressure causes the lock lever of the vertical
transport door to deform (see the photo to the right) over time.
As a result, the door is incompletely shut and creates an
unwanted gap in the paper path where the leading edge of the
paper curls.
SOLUTION
Production line:
The following 2 brackets were added to prevent the locking
lever from deforming and shifting the position of the lock on the
mainframe.
P/N: D1356641
P/N
D1356641
BRACKET:FIX:LEVER:VERTICAL TRANSPORT
D1356642
BRACKET:FIX:LEVER:VERTICAL TRANSPORT:LOWER
04583012N
HEXAGON HEAD TAPPING SCREW:3X12
T
echnical

Troubleshooting

Mechanical
Paper path
Product Safety
P/N: D1356642
B
ulletin
Date:12-May-14
Prepared by:
Part information
Electrical
Transmit/receive
Other (
)
Description
PAGE: 1/3
No: RD135126
Takeshi Toriumi
Action required
Service manual revision
Retrofit information
Tier 2
Q'ty
Note
1
Add
1
Add
1
Add

Advertisement

Table of Contents
loading