Assignment Of The Digital Outputs: - Siemens SINUMERIK 802C Manual

Hide thumbs Also See for SINUMERIK 802C:
Table of Contents

Advertisement

Manual Machine
7.8
I/O assignment in the standard PLC program
7.8.2

Assignment of the digital outputs:

1st module:
O 0.0
O 0.1
Pulse enable drive I/RF module
O 0.2
Pulse enable drive
O 0.3
Coolant pump ON
O 0.4
Secondary power ON
O 0.5
Fault general
O 0.6
Fault lubrication
O 0.7
O 1.0
Ready
O 1.1
O 1.2
O 1.3
Lubrication axes
O 1.4
O 1.5
O 1.6
O 1.7
2nd module:
O 2.0
Spindle contactor (control)
O 2.1
O 2.2
Bypass axis limit switch
O 2.3
O 2.4
O 2.5
O 2.6
O 2.7
O 3.0
O 3.1
O 3.2
O 3.3
O 3.4
O 3.5
O 3.6
O 3.7
7-132
X2005
Pin 2
DO 0
X2005
Pin 3
DO 1
X2005
Pin 4
DO 2
X2005
Pin 5
DO 3
X2005
Pin 6
DO 4
X2005
Pin 7
DO 5
X2005
Pin 8
DO 6
X2005
Pin 9
DO 7
X2006
Pin 2
DO 8
X2006
Pin 3
DO 9
X2006
Pin 4
DO 10
X2006
Pin 5
DO 11
X2006
Pin 6
DO 12
X2006
Pin 7
DO 13
X2006
Pin 8
DO 14
X2006
Pin 9
DO 15
X2005
Pin 2
DO 0
X2005
Pin 3
DO 1
X2005
Pin 4
DO 2
X2005
Pin 5
DO 3
X2005
Pin 6
DO 4
X2005
Pin 7
DO 5
X2005
Pin 8
DO 6
X2005
Pin 9
DO 7
X2006
Pin 2
DO 8
X2006
Pin 3
DO 9
X2006
Pin 4
DO 10
X2006
Pin 5
DO 11
X2006
Pin 6
DO 12
X2006
Pin 7
DO 13
X2006
Pin 8
DO 14
X2006
Pin 9
DO 15
SINUMERIK 802C
6FC5 597–3AA20–0BP2 (01.02)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents