Start-Up
4.7
Commissioning
Once entered, these data are immediately written to the data memory.
The machine data are activated depending on the Activation setting of the appropriate ma-
chine data, Section 4.1.2.
Note
Since these data are only stored in the memory backed up for a limited period of time, a data
backup is necessary (see Section 4.1.4).
Machine data
The following machine data list contains all general and other machine data and setting data,
which can be changed if necessary.
Number
10074
Division ratio of the PLC task factor for main run
11100
Number of auxiliary function groups
11200
Standard machine data loaded on next Power On
11210
MD backup of changed MD only
11310
Threshold for direction change of handwheel
11320
Handwheel pulses per detent position (handwheel number): 0...1
20210
Maximum angle for compensation blocks with TRC
20700
NC-Start disable without reference point
21000
Circle end point monitoring constant
22000
Auxiliary function group (aux. fct. no. in channel): 0...49
22010
Auxiliary function type (aux. fct. no. in channel): 0...49
22030
Auxiliary function value (aux. fct. no. in channel): 0...49
22550
New tool compensation for M function
Setting data
Number
41110
Jog feedrate
41200
Spindle speed
42000
Start angle
42100
Dry run feedrate
4-74
Description
Explanation
Default
Value
2
1
O
H
0FH
2
1
100
1
0.01
1
""
0
0
Default-
Value
0
0
0
5000