5.3
Update errors
Table 5-1
Update errors
Error Text
ERROR
Error when updating the system software via V24
S

UPDATE

Data already in receive buffer (send from PC
side started too early)
S
Error when erasing the FLASH memory
S
Error when writing to the FLASH memory
S
Inconsistent data (incomplete or faulty)
SINUMERIK
Update without programming the code FLASH
802S
completed (no data received, transfer not started)
UPDATE
NO DATA
SINUMERIK 802C
6FC5 597–3AA20–0BP2 (01.02)
Explanation
Software Update
5.3
Update errors
Remedial Action
S
Repeat update
S
Check link between control system
and PC/PG
S
Check diskette