Return Values/Error Codes From Gang430.Dll; Return Values/Error Codes - Texas Instruments MSP430 User Manual

Gang programmer
Hide thumbs Also See for MSP430:
Table of Contents

Advertisement

Return Values/Error Codes From GANG430.DLL

4.2
Return Values/Error Codes From GANG430.DLL
Status
ERR_NONE
ERR_COMM
ERR_OPEN_COMM
ERR_CLOSE_COMM
ERR_SET_COMM_STATE
ERR_SYNC
ERR_RX_HDR_TIMEOUT
ERR_CMD_NOT_COMPLETED
ERR_CMD_FAILED
ERR_WRONG_BAUDRATE
ERR_READ_INI
ERR_BAD_RECORD
ERR_FILE_END
ERR_FILE_IO
ERR_FILE_DETECT
ERR_FILE_OPEN
ERR_ARGUMENT
ERR_IMAGE_CORRUPTED
ERR_IMAGE_JTAGPORT
ERR_IMAGE_DATAPORT
ERR_IMAGE_HANDSHAKE
ERR_TARGET_JTAGPORT
ERR_TARGET_VOLTAGE
ERR_SYSTEM_VOLTAGE
ERR_BLOWFUSE_VOLTAGE
ERR_TARGET_NOACCESS
ERR_VERIFY_FAILED
ERR_NO_PARMS
ERR_IMAGE_ERASE
ERR_IMAGE_LOAD
ERR_PARMS_LOAD
ERR_SEL_BAUDRATE
ERR_SET_VCC
ERR_WRONG_CMD
ERR_LOW_SUPPLY_VOLTAGE
WNG_LOW_VCC_IN
ERR_WRONG_DEVICE
ERR_DEVICE_MEM_MISMATCH
ERR_NO_DEVICE
ERR_IMAGE_OVERWRITTEN
54
Dynamic Link Library GANG430.DLL
Table 4-1. Return Values/Error Codes
Return
Value
0
Operation successful
1
Communication − Frame has errors
2
Unable to open COM port − already in use?
3
Unable to close COM port
4
Unable to modify COM port state
5
Synchronization failed. Programmer connected?
6
Timeout during operation − Correct COM port selected?
7
Command did not complete correctly
8
Command failed or not defined or Target not accessible
9
Wrong baud rate specified
10
Could not read GANG430.ini
11
File contains invalid record
12
Unexpected end of file
13
Error during file I/O
14
Selected file is of unrecognizable format
15
Unable to open file
16
Function argument(s) out of range
31
Image Memory corrupted or erased
32
Self test − No JTAG access to Image Buffer device
33
Self test − Data connections to Image Buffer device invalid
34
Self test − No access to one ore more Image Buffer devices
35
Self test − No JTAG access to one or more Target channels
36
Self test − Target Voltage Generator (VCCT) does not work properly
37
Self test − System Voltage (VCC) not in range
38
Self test − Blow Fuse Voltage (VPP) not in range
39
Target not accessible
40
Verification failed
41
Main Process Parameters not yet set
42
Could not erase Image Buffer
43
Could not load Image Buffer
44
Could not load Main Process Parameters
45
Could not select Baud Rate
46
Could not set target voltage (VCCT) − Short circuit or settling time too short
47
Invalid firmware command
48
Power supply voltage too low
49
Sense voltage out of range − Check pin MSP_VCC_IN
50
Wrong target device connected (target doesn't match selected device)
51
Image doesn't fit memory model of selected device.
52
No target device connected
Code data saved to already used location (overwritten). Check code file_1
53
and file_2 if contains data in the same locations.
Copyright © 2003–2010, Texas Instruments Incorporated
Comment
SLAU101O – March 2003 – Revised May 2010
www.ti.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msp-gang430

Table of Contents