B2: Dc Inj / Short Ckt Brake - Omron Q2A Series Technical Manual

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

11.3 b: APPLICATION
No.
Name
(Hex.)
b1-15
Freq. Ref. Sel. 2
(01C4)
b1-16
Run Comm. Sel 2
(01C5)
b1-17
RUN@PowerUp
Selection
(01C6)
b1-21
CLV Start Selection
(0748)
Expert
b1-35
DI Deadband Time
(1117)
Expert

b2: DC INJ / SHORT CKT BRAKE

No.
Name
(Hex.)
b2-01
ZSpd/DCI Threshold
(0189)
b2-02
DCI Braking Current
(018A)
b2-03
DCInj Time@Start
(018B)
b2-04
DCInj Time@Stop
(018C)
b2-08
MagFlux Comp Value
(0190)
b2-12
SCB Time@Start
(01BA)
b2-13
SCB Time@Stop
(01BB)
b2-18
SCB Current
(0177)
398
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the input method for frequency reference 2.
0 : Keypad
1 : Analog Input
2 : Modbus
3 : Option PCB
4 : Pulse Train Input
V/f
CL-V/f
OLV
CLV
AOLV
Sets the input method for Run Command 2 when the user switches the control circuit
terminals ON/OFF to change the Run command source.
0 : Keypad
1 : Analog Input
2 : Modbus
3 : Option PCB
V/f
CL-V/f
OLV
CLV
AOLV
Sets drive response when energizing a drive that has an external Run command. Set this
parameter in applications where energizing or de-energizing the drive enables the Run
command.
1 : Disregard RUN
2 : Accept RUN
V/f
CL-V/f
OLV
CLV
AOLV
Sets drive response to a Run command when A1-02 = 3 or 7 [Control Method =
CLVector or PM CLVector]. Usually it is not necessary to change this setting.
1 : Reject RUN
2 : Accept RUN
V/f
CL-V/f
OLV
CLV
AOLV
Sets the deadband time for MFDIs.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency to start DC Injection Braking, Short Circuit Braking, and Zero Servo.
Note:
This parameter is available when b1-03 = 0 [Stopping Method Selection = Ramp-
>Stop].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the DC Injection Braking current as a percentage of the drive rated current.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the DC Injection Braking Time at stop. Sets the zero speed control at stop in CLV,
AOLV, or CLV/PM.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the DC Injection Braking Time at stop. Sets the zero speed control at stop in CLV,
AOLV, or CLV/PM.
V/f
CL-V/f
OLV
CLV
AOLV
Sets how much current the drive injects when DC Injection Braking at Start starts
(Initial Excitation) as a percentage of E2-03 [Mot No-Load Current].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Short Circuit Braking time at start.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Short Circuit Braking time at stop.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Short Circuit Braking Current as a percentage of the motor rated current.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Default
Ref.
(Range)
0
523
(0 - 4)
0
525
(0 - 3)
1
526
(1, 2)
1
526
(1, 2)
0.0 ms
527
(0.0 to 100.0 ms)
Default
Ref.
(Range)
Determined by A1-02
527
(0.0 - 10.0 Hz)
50%
528
(0 - 100%)
A1-02 = 4: 0.03 s
528
Other than A1-02 = 4:
0.00 s
(0.00 - 10.00 s)
Determined by A1-02
528
(0.00 - 10.00 s)
0%
529
(0 - 1000%)
0.00 s
529
(0.00 - 25.50 s)
A1-02 = 8: 0.00 s
529
Other than A1-02 = 8:
0.50 s
(0.00 - 25.50 s)
100.0%
530
(0.0 - 200.0%)