Acoustic Indicators - Fujitsu PRIMERGY RX2540 M4 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX2540 M4:
Table of Contents

Advertisement

Pos. Indicator
PSU status
1
indicator

17.2.4 Acoustic indicators

PEI Beep Codes
Pre-EFI Initialization (PEI) - memory Initialization (bootblock)
# of
Description
Beep
1
Memory not installed
2
Recovery started
4
Recovery failed
DXE Beep Codes
Driver Execution Environment (DXE) - main hardware Initialization (POST)
RX2540 M4
Status
Description
flashing
The server is switched off, but mains
green
voltage is present (standby mode).
The server is switched on and operating
green on
properly.
An overload has been detected. The
flashing
PSU is still running, but failure might be
orange
imminent.
An PSU failure has been detected.
Possible causes:
orange on
– Over/under voltage
– Overheating
– Fan failure
Action
Ê Check if the memory module is installed.
Ê Check if the memory module is installed
correctly.
Recovery procedure is initialized by jumper
settings on the system board and announced
with two beep.
This is only an information.
Ê Restart the recovery procedure again.
Ê If the same beep code sounds again,
replace the system board.