5.9

Canopy drive

In order to guarantee a trouble-free operation of the canopy
Regular
drive, check and service the spring ropes each time the tubes
maintenance
are replaced. (see table step 1-2)
If the canopy does no longer remain firmly in the upper position,
Tightening the
the two springs have to be re-tightened. For that purpose you
springs
Step
1
Check the ropes for wear. If individual wires of the rope
are spliced, always replace both ropes.
2
Remove the lateral pane.
3
Both at the right-hand and at the left-hand side you will
have free access to the tension screws. When you have
an XXL-unit remove the cover plates.
4
Tighten both springs in a balanced way.
5
Check the canopy drive: the canopy remains firm in any
position.
6
Close the lateral pane.
Illustr. 5-18 Left tension screw
Procedure
Illustr. 5-19 Right tension screw
Operation and Service megaSun 6900
Reference
see 5.2
Illustr. 5-18
Illustr. 5-19