Step
1
Open the lower front cover and check the following
items in regular intervals:
2
The air hose of the air-conditioning unit must not have
any kinks.
3
The filter mats in the base section and in the canopy
section must be clean.
4
Check the exhaust air hose for kinks or damages,
and if there is an additional ventilator due to hose
overlength, check its function as well.
5
An adequate ventilation and air extraction in the studio
must be guaranteed at any time.
6
Check the correct position of the duct pane to make
sure that the base pane is adequately cooled.

5.11 Air-conditioning unit

Air hose
Condensation
hose leads
outside to the
condensate tank
Condensate pump
30
Checks
Operation and Service megaSun 6900
A clean and trouble-free exhaust air system prevents the
apparatus from overheating. The maximum hose length of 6 m
must not be exceeded unless there is an additional ventilator.
Procedure
Fan
Check the heat exchangers of the air-conditioning unit for dirt
particles each time a tube is replaced. Dirty heat exchangers
reduce the performance of the air-conditioning unit.
Open the front cover and vacuum-clean the heat exchangers, if
necessary.
Check the connection hose each time the tubes are replaced.
Defective hoses must be replaced.