Maintenance
8.5 Mounting bracket fastening
Procedure
1. Select the new position for the connectivity module on the motor. Two positions for the
connectivity module on the motor are shown as example in the following diagrams.
2. Apply the adhesive to the recommended locations on the inner side of the mounting bracket.
Carefully ensure that no adhesive enters the threads for the fastening screws.
3. Place the mounting bracket on the motor cooling ribs. The short arm of the mounting bracket
must be in complete contact with a cooling rib. The long mounting bracket arm must be in
contact with one or several edges of the cooling ribs.
4. Press the mounting bracket onto the motor cooling ribs using your hand.
5. Allow the adhesive applied to the mounting bracket to dry. Carefully comply with the usage
instructions provided on the adhesive package.
6. Mounting the connectivity module onto the bracket (Page 38).
7. Allow the adhesive to completely dry.