Mounting and installation
5.1 Connecting the battery
Requirements
● Visually inspect the battery for any damage.
● You require a Torx® T 20 screwdriver.
Procedure
1. At the front cover of the connectivity module release the 2 fastening screws.
Do not completely turn the screws from the cover so that the screws are not lost.
2. Remove the front cover.
3. Insert the battery connector by gently pressing on the socket provided. It is not possible to
incorrectly insert the connector as a result of the connector coding used.
The connectivity module LED lights for approx. 20-30 seconds for a battery test.
4. Reattach the front cover. Carefully ensure that the cover is precisely in the correct position.
5. Tighten the two screws by hand. The thread can be damaged if too much force is applied.