Fault Detection - YASKAWA iQpump Micro CIMR-PW Series User Manual

Ac drive compact intelligent pump controller
Table of Contents

Advertisement

6.3

Fault Detection

Fault Displays, Causes, and Possible Solutions
u
LED Display
LCD Display
AJF
Anti-Jam Fault
Cause
The drive was not able to clear debris from
the impeller in fewer than the number of
attempts set in P7-02. This is only effective
when P7-01, Anti-jam Operation is set to 1
(enabled).
LED Display
LCD Display
bv5
Cause
No signal was received from the PLC
Faulty communications wiring or an existing
short circuit
Communication data error occurred due to
noise
The option card is damaged
The option card is not properly connected to
the drive
LED Display
LCD Display
ce
Cause
Faulty communications wiring or an existing
short circuit
Communication data error occurred due to
noise
LED Display
LCD Display
cpf02
CPF02
Cause
Control circuit is damaged
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
Table 6.2 Detailed Fault Displays, Causes, and Possible Solutions
AJF
Anti-Jam Fault
• Check for proper pump operation. Remove debris from the pump impeller.
• Adjust the P7-03 level or the P7-02 counts.
• Drive response to this condition is controlled by P7-01, Anti-jam Operation Selection.
Option Communication Error
• The connection was lost after establishing initial communication.
bUS
• Only detected when the run command frequency reference is assigned to an option card.
• Check for faulty wiring.
• Correct the wiring.
• Check for disconnected cables and short circuits and repair as needed.
• Check the various options available to minimize the effects of noise.
• Counteract noise in the control circuit, main circuit, and ground wiring.
• Ensure that other equipment such as switches or relays do not cause noise. Use surge absorbers if
necessary.
• Use only recommended cables or other shielded line. Ground the shield on the controller side or the
drive input power side.
• Separate all communication wiring from drive power lines. Install an EMC noise filter to the drive power
supply input.
Replace the option card if there are no problems with the wiring and the error continues to occur.
• The connector pins on the option card do not line up properly with the connector pins on the drive.
• Reinstall the option card.
MEMOBUS/Modbus Communication Error
CE
Control data was not received for the CE detection time set to H5-09.
• Check for faulty wiring.
• Correct the wiring.
• Check for disconnected cables and short circuits and repair as needed.
• Check the various options available to minimize the effects of noise.
• Counteract noise in the control circuit, main circuit, and ground wiring.
• Use only recommended cables or other shielded line. Ground the shield on the controller side or the
drive input power side.
• Ensure that other equipment such as switches or relays do not cause noise. Use surge suppressors if
required.
• Separate all communication wiring from drive power lines. Install an EMC noise filter to the drive power
supply input.
A/D Conversion Error
An A/D conversion error or control circuit error occurred.
• Cycle power to the drive.
• If the problem continues, replace the drive.