Wire Sprayers with
Explosion-Proof Heaters
(Hazardous location sprayers only)
If your sprayer is rated for hazardous areas, and you
have explosion-proof heaters, you must have a quali-
fied electrician connect heater wiring. Ensure wiring
and installation comply with local electrical codes for
hazardous areas.
Improperly installed or connected equipment will create
a hazardous condition and cause fire, explosion, or elec-
tric shock. Follow local regulations.
When explosion-proof heaters are used, ensure wiring,
wiring connections, switches, and electrical distribution
panel all meet flame-proof (explosion-proof) require-
ments.
Refer to Viscon HP heater manual 309524 for electrical
connection instructions and guidelines in hazardous
locations.
312359J

Connect Air Supply

Connect air supply line to 3/4 npt(f) air filter inlet.
NOTE:
Use a 3/4 in. (19.1 mm) ID minimum air hose.
E
NOTE:
Air supply requirement: 150 psi (1.0 MPa, 10.3 bar)
maximum; 50 psi (0.35 MPa, 3.5 bar) minimum (while
running).
Flow volume required: 70 scfm (1.96 m
3
250 scfm (7.0 m
/min) maximum. Available fluid pres-
sure and flow rate are directly related to available air vol-
ume. See Pump Performance Charts, page 83.
General flow volume guidelines:
70 scfm (1.96 m
spraying
10 scfm (0.28 m
10 scfm (0.28 m
pump
NOTE:
If your sprayer is for use in hazardous areas, the control
box is powered by an air-driven alternator.
NOTE:
Dosing valves are operated by air. The sprayer will not
operate correctly if the inlet air gauge drops below 50
psi (0.35 MPa, 3.5 bar) while spraying.
3
/min) minimum;
3
/min) per gpm (lpm) while
3
/min) added per agitator
3
/min) added per drum feed
Setup
21