Shutdown Entire System

Follow this procedure prior to servicing equipment or
shutdown.
1. Follow Flush Mixed Material, page 36. Use a metal
pail lid with a splash guard to avoid splashing.
312359J
TI1953a
2. Engage trigger lock, turn off air regulator, and close
main air shutoff valve. Remove spray tip.
TI1949a
3. For overnight shutdown:
Follow Park Fluid Pump Rods on page 38.
Cap fluid outlets to keep solvent in the lines.
Fill pump A and B packing nuts with throat seal
liquid (TSL).
Shutdown Entire System
TI1948a
39