Battery Problems; Reloading Look Up Table Values; Resetting Filter Correction Values - AGFA PCR II Plus User Manual

Film recorder
Table of Contents

Advertisement

Battery Problems

When you turn on the film recorder, it checks look up table, color fil-
ter correction and DAC values. These values are stored in memory
powered by a back-up battery. If an error is detected, one of the these
messages appears in the message window:
?LUT CHECKSUM ERROR
The look-up table values for the current film module (and maybe
others) have been corrupted. To reload them, follow the procedure
Reloading Look Up Table Values in this section.
• BATTERY! ERROR
The factory-set color filter correction and DAC values are no longer
intact. To reset them, follow the procedures Resetting Filter Correc-
tion Values in this section.

Reloading Look Up Table Values

Follow this procedure to reload look up table values:
Step 1:
Press the RESET button on the PCR II Plus front panel to
clear the error message and render the unit operational.
Step 2:
Next, to reload and store default brightness and contrast set-
tings, select the SET FILM TYPE function via the front panel
display.
Step 3:
To customize brightness and contrast settings, follow the
procedures described in Chapter 6. If the error message ap-
pears again after power-up, call for service.

Resetting Filter Correction Values

In the event of a battery failure, enter the color correction filter values
recorded on the label on the back panel. Follow this procedure:
Step 1:
Press RESET to clear the BATTERY! ERROR message.
Step 2:
Press MENU once, then press PREVIOUS or NEXT until the
message SET BRIGHTNESS SELECT FUNCTION appears.
7-8 • PCR II Plus User Guide