Certified Quality / Definition; Scope Of Delivery; Transport Damage; Installation Instructions - Spartherm XS 500 Installation And Operating Instructions Manual

Linear fireplace cassettes
Table of Contents

Advertisement

1. CERTIFIED QUALITY / DEFINITION

Our fireplace cassettes are tested according to DIN 13229.
This family of cassettes can be installed in five standard sizes (500-900)
into, for example, existing open fireplaces. However, it is also possible to
install the fireplace cassette in a similar way to a fireplace insert if the
appropriate tests have been completed. This includes taking into account
the relevant sizes of the air supply and recirculation openings.
The fireplace cassettes have a self-closing firebox door so that the door
is only opened for operating the fireplace (e.g. cleaning the firebox or for
putting more fuel on the fire). It is not permitted to tamper with the closing
mecha-nism for safety reasons and should this occur it will invalidate the
guarantee and the approval to use the fireplace cassette. The guarantee and
the approval to use the fireplace cassette are also invalidated if the cassette
is technically modified in any other area by the customer.

1.1 SCOPE OF DELIVERY

A fireplace cassette with the following characteristics:
• Firebox made of refractory concrete/vermiculite
• Primary and secondary airflow systems
• Self-closing firebox door with a high temperature-resistant ceramic
glass panel
• Heat-resistant gloves
• Type plate (mounting location, see 5.2)

1.2 TRANSPORT DAMAGE

Please immediately check the goods on delivery (visual inspection). Note
any damage that may have occurred on your delivery note and then please
inform your fireplace fitter. Protect the visible parts of the cassette from
soiling or damage during installation.Only approved transport aids with suf-
ficient load-bearing capacity may be used for transporting your fireplace
cassette. The following points must be observed for safe and uncomplicated
transport:
• The fireplace cassette must generally only be transported either in an
upright position or slightly inclined onto its rear!
• If a hand truck is being used as a transport aid, this may only be posi-
tioned at the rear of the cassette.

2. INSTALLATION INSTRUCTIONS

Your fireplace cassette may only be assembled and installed by a specialist
fireplace fitter. You should talk to the responsible heating inspector/chimney
sweep in your district before setting up and installing the fireplace cassette
in order to clarify the suitability of your chimney and installation location, as
well as for any other possible issues.
GB 5
GB

Advertisement

Table of Contents
loading

This manual is also suitable for:

S 600M 700L 800Xl 900

Table of Contents