4g. Connect the cable wires to the terminals on the blower as shown and
to the control box for the speed regulator.
Blower connection cable
After the cables have been connected, check and ensure proper function-
ality before finishing the installation. The cables must be fixed using the
holding flaps. The flaps can either by pressed in from the outside or levered
out from the inside. Once the cable has been pushed under the flaps, the
flaps must then be pushed down lightly onto the cable.
PLEASE NOTE: Do not press on the flaps too hard because otherwise the
cable could become damaged!
4h. Pull the rubber knob off the front of the control shaft and twist off the
nut and ring washer. The control shaft is inserted through two holes in
the frame when installing the frame. It may be necessary to order a
new cassette frame if the existing one does not have any corresponding
holes
Mains supply
4.7 DISMANTLING AND INSTALLING THE FIREBOX
DOOR
Please follow the following steps to dismantle / install the firebox door.
Take care when carrying out these tasks as otherwise damage to the casing
/ door cannot be ruled out. We recommend protecting the casing / metal
plates with an overlay.
Dismantling:
1. Use a screwdriver or a similar tool to
remove the safety clasp on the stop-per
side (hinge side) of the door.
2. Swing the door open. Then tighten the
Allen screw on the lower hinge with a 3
mm Allen key.
3. Take hold of the door at the bottom.
Raise the door a little with a light lifting
movement so that the lower pin of the
hinge is exposed.